Cooling thermostat Proline Kryomat RP 4050 CW -50…200 °C water-cooled
Cooling thermostat Proline Kryomat RP 4050 CW -50…200 °C water-cooled
LAUDA Proline Kryomat RP 4050 CW cooling thermostat 400 V; 3/N/PE; 50 Hz Performance features: bath/circulation thermostat with state-of-the-art microprocessor technology, extensive programming and info functions, and integrated cooling system. High-resolution backlit graphic LCD screen with individually selectable display functions. Additional green LED display for temperature. Input options via cursor keys and numerical softkeys. Additional Tmax button for overtemperature. Removable control console for remote control. EasyUse system for simple operation of the entire device. SelfCheck assistant for system diagnostics. Fully electronic continuous controller with PID behaviour for internal and external control. PowerAdapt system for optimally adapted maximum heating power without overloading the power supply. Low-level and overtemperature protection for operation with non-flammable liquids. Standard integrated optically isolated RS 232/485 interface. Retrofittable with up to 2 additional interface modules (RS 232/485, Profibus, analogue or contact modules, Ethernet-USB module). Programmer with 150 temperature/time segments, divisible into 5 programs. Timer function for switching on the thermostat, switching to stand-by mode or executing programs. LAUDA Variopump with 4 selectable power levels. Application-related adjustment of bath circulation. Pump connections at the rear and side, integrated bypass. SmartCool system for energy-saving digital refrigeration control including automatic compressor control. Electronically controlled bath rim and bath bridge heating prevents condensation and icing of air humidity at low temperatures. Condenser cooling water. Operation with non-flammable refrigerant (HFC), compliant with the F-Gas Regulation Regulation (EU) 573/2024. Technical data (according to DIN 12876): Operating temperature range: -50 ... 200 °C. Ambient temperature range: 5 ... 40 °C. Temperature constancy: 0,05 ± K. Maximum heating power: 3,5 kW. Maximum power consumption: 5 kW. Current consumption: 16 A. Pump maximum pressure: 0,5 bar. Pump maximum flow rate (pressure): 19 L/min. Minimum / maximum bath volume: 32,0 / 44,0 L. Bath size (WxDxH): 350 x 350 x 250 mm. Recommended cooling water temperature: 15 °C. Cooling water consumption: 11,7 L/min. Maximum cooling water pressure: 10 bar. Dimensions (WxDxH): 600 x 700 x 1216 mm. Weight: 124 kg. Refrigerant stage 1: R-449A (GWP 1397); 1,600 kg; 2,2 t CO2-eq. Mains supply: 400 V; 3/N/PE; 50 Hz. Mains plug: power cable with plug (IEC 60309, 5-pole, CEE, red, 16 A). Cooling capacity (pump level): 200 °C (2); thermal oil; 6 kW. 20 °C (2); ethanol; 6 kW. 0 °C (2); ethanol; 3,5 kW. -20 °C (2); ethanol; 1,8 kW. -30 °C (2); ethanol; 1,1 kW. -40 °C (2); ethanol; 0,6 kW. -50 °C (2); ethanol; 0,25 kW. Standard accessories: 1 bath cover. 4 union nuts, 4 sealing plugs. 2 hose olives 13 mm for pump connection
-
Reference9017894
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
4 other products in the same category
Proline Kryomat RP 3090 CW thermostat, -90…200 °C
Rated out of 5 stars based on
review(s)
LAUDA Proline Kryomat RP 3090 C cooling thermostat -90…200 °C air-cooled
Rated out of 5 stars based on
review(s)
Proline Kryomat RP 4090 CW cooling thermostat -90…200 °C
Rated out of 5 stars based on
review(s)
Viewed products
Volumetric pipette 50 ml AR glass Class AS, 2 marks, brown graduated, pack of 6
€121.32
Rated out of 5 stars based on
review(s)
Splash head to Stutzer with Cone and Socket straight Cone NS29/32 Socket NS29/32
€73.37
Rated out of 5 stars based on
review(s)
Safety cabinet S90.129.060 Safety Yellow 596x616x1298 mm
Rated out of 5 stars based on
review(s)
Analytical balance ALJ 210-5A weighing range 210 g readability 0,00001 g
€2,946.30
Rated out of 5 stars based on
review(s)
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent